Applications: ideal for high and large space (H: 4-30m) and uses PTC electric heating with max 16m supply air height. Heating capacity can be customized.

Model: AirTS-ED-I, AirTS-ED-II

Function: heating

Hot source: PTC

Control mode: wireless control, variable frequency, auto monitoring

Quality Assurance

Quality Assurance

After-sales Service

After-sales Service

Working Principle

When PTC heater starts working, the efficient heat exchanger in the equipment is used to achieve rapid heating of the air.

The large wind pressure axial fan installed on the top is used to forcedly press the hot air down. Then the air is subject to pressure boost twice through the silencer sponge and the lower trapezoidal convergence, swirls out from the nozzle through the guide vane and is distributed throughout the space from top to down.


Features

By adjusting wind speed and air outlet angle, it achieves comfortable heating environment


Supply air angle stepless regulation


Utilize axial fan to efficiently recover heat from the top, reducing heat loss from the roof, achieving energy-saving effects


High: continuously recover heat from the top space to send the heat to the working area at the bottom

Large: the devices in the space are arranged uniformly with even heat distribution


Space: decrease the temp of roof and surrounding walls, decrease the temp difference with the outside, and reduce heat loss


Long air supply distance, high hot air volume


Function: heating

Functions

Fall prevention warning monitoring

Working data collection and analysis

Electric Heating

Wireless intelligent control

Filter net self-cleaning

Wireless control

Support full linkage control

Light breeze air supply

Technical Comparison

AirTS top heating unit

AirTS top heating unit

High and large space air conditioner lifted on the roof


It achieves heating air from the air exchanger in the equipment


It distributes the hot air by means of efficient air distributor, which eliminate the undesirable indoor temp layers


Comfortable heating environment without wind feeling sense


Bottom heating unit

Bottom heating unit

In high large space with great depth, using radiator can allow natural air convection as hot air rises


It can only radiate into small area with the range less than 5m. The heat rising to the roof will be dissipated and the temp cannot be achieved effectively in the middle area.


Radiator heating requires high requirements for supply water temp.

AirTS units temp field

Our heating units forcedly and quickly send the hot air down, make the temp in the working area rise rapidly.


Radiator heating temp field

It can be seen from the radiator heating temp field image that the heat is mainly gathered on the roof and the temp is low in the lower working area.

Specification

Recirculated Air Electric Heating Unit

Recirculated Air Electric Heating Unit
Model
AirTS-ED-IAirTS-ED-II
Rotating speed of fanr/min0~9000~860
Standard circulating air volumem³/h0~67000~9700
VoltageV380±5%380±5%
Electric powerkW0~0.850~1.80
CurrentA0~1.650~3.60
Suitable installation heightm4~104~17
PTC heater control mode
LinkageLinkage
Control mode
VAV stepless regulation
VAV stepless regulation
Noise
dB<60<60

Recirculated Air Electric Heating Unit

Dimension
Model
AirTS-ED-IAirTS-ED-II
Amm
9001100
Bmm
12001505
Cmm735920
Emm100100
Fmm150
150
Gmm480568
Hmm
765
935
Jmm
170
180
K
mm
400
400
Weight
kg
120
170

Application


                

                

Download

Look forward to hearing from you

Welcome friends and customers at home and abroad to cooperate sincerely and create brilliance together!

Service E-mail: [email protected]

Contact Us
You may also like >

        

        
    
Tags: Heating Unit

Tel:

+86 136 7509 6029

WhatsApp:

+86 136 7509 6029

[email protected]
+86 136 7509 6029

+86 136 7509 6029