Louvered Recirculated Air Heating Unit

Applications: ideal for high and large space (H: 4-30m) that needs heating with max 23m supply air height.

Model: AirTS-DM-I, AirTS-DM-II

Function: heating

Hot source: hot water (40-90℃) /steam (<120℃)

Control mode: wireless control, variable frequency, auto monitoring

Quality Assurance

Quality Assurance

After-sales Service

After-sales Service

Working Principle

When hot water or steam passes the equipment, the efficient heat exchanger in the equipment is used to achieve rapid heating of the air.

The large wind pressure axial flow fan installed on the top is used to forcedly press the hot air down. Then the air is subject to pressure boost twice through the silencer sponge and the lower trapezoidal convergence, swirls out from the nozzle through the guide vane and is distributed throughout the space from top to down.

Functions

Fall prevention warning monitoring

Working data collection and analysis

Variable air volume and water volume

Wireless intelligent control

Filter net self-cleaning

Function: heating

Support full linkage control

Light breeze air supply

Technical Comparison

AirTS top heating unit

AirTS top heating unit

High and large space air conditioner lifted on the roof


It achieves heating air from the air exchanger in the equipment


It distributes the hot air by means of efficient air distributor, which eliminate the undesirable indoor temp layers


Comfortable heating environment without wind feeling sense


Bottom heating unit

Bottom heating unit

In high large space with great depth, using radiator can allow natural air convection as hot air rises


It can only radiate into small area with the range less than 5m. The heat rising to the roof will be dissipated and the temp cannot be achieved effectively in the middle area.


Radiator heating requires high requirements for supply water temp.

AirTS units temp field

Our heating units forcedly and quickly send the hot air down, make the temp in the working area rise rapidly.


Radiator heating temp field

It can be seen from the radiator heating temp field image that the heat is mainly gathered on the roof and the temp is low in the lower working area.


Specification

Louvered Recirculated Air Heating Unit

Louvered Recirculated Air Heating Unit

Model
AirTS-DM-IAirTS-DM-II
Rotating speed of fanr/min0~13000~860
Standard circulating air volumem³/h0~55000~10500
VoltageV380±5%380±5%
Electric powerkW0~0.850~1.80
CurrentA0~1.650~3.60
Suitable installation heightm4~84~17
Control mode
VAV stepless regulation
VAV stepless regulation
Noise
dB<59<65

Louvered Recirculated Air Heating Unit

Dimension

Model
AirTS-DM-IAirTS-DM-II
Amm
710
1110
B
mm
600
800
Cmm
492
850
Emm
175
150
Fmm
100
100
Jmm
467
320
Kmm
418
240
N (internal thread)mm
DN25
DN40
Weight
kg
85
125
Water volume
L
4.35
9.8

Application


                

                

Download

Look forward to hearing from you

Welcome friends and customers at home and abroad to cooperate sincerely and create brilliance together!

Service E-mail: [email protected]

Contact Us
You may also like >

        

        
    
Tags: Heating Unit

Tel:

+86 136 7509 6029

WhatsApp:

+86 136 7509 6029

[email protected]
+86 136 7509 6029

+86 136 7509 6029